DATA CENTER & AI LIQUID COOLING
High density computing with
Immersion-cooled rack servers
for data centers & AI
As software becomes more sophisticated and demanding, the requirements for hardware infrastructure are intensifying. The ability to increase compute power is a must.
LiquidCool Solutions’ is up to the challenge.
Designed for data centers and AI, the zero-pressure ZPServer offers maximum scalability with up to 4kW per standard rack unit.
It’s configured with the latest components to meet your high capacity cooling requirements, form factor and OEM brand agnostic. And it’s flexible — can be co-located in existing 19” racks or packaged from top-to-bottom to provide the highest density TDP in its own rack.
Using our patented Total Liquid Immersion with Directed Flow™ (TIDF) technology, we send the coolest fluid to the hottest electronic components first within our liquid-tight chassis. Then the thermal transfer fluid immerses the other electronics to gather the remaining heat before leaving the chassis to be cooled and returned.
This is the most energy efficient and environmentally sound way to remove heat from data centers, reducing PUE to <1.03.
See how you’ll save on capital and operating expenses >>
Learn more about our technology >>
features
- Uses standard data center racks
- Energy efficient — cooling PUE <1.03
- No air conditioning
- No water
- High power density
- Siting flexibility
- High reliability
- Quiet operation. No fans.
- Easy to maintain
specifications
Your LCS ZPServers will be configured based on your application’s needs. We are brand and form factor agnostic.
Processors
Intel® Xeon® Scalable
or AMD EPYC™ Server
Accelerators / GPUs
NVIDIA™ | AMD™ | Intel®
I / O
Motherboard dependent
Power supply
System dependent
External / Power-shelf
Facility power required 240/120VAC
Form factor
2U server
Standard 19″ rack EIA & OCP
Configured per your application
Chassis
Rugged sealed enclosure protects electronics from oxidation, corrosion, dust, dirt, salt, humidity, and ESD.
Dimensions
Width: 18″ 45.72 cm
Depth: 33″ 83.82 cm
Height: 3.5″ 8.89 cm
Fluid capacity
Approx 5 gallons per 2 rack units
Single-phase dielectric heat transfer fluid
WET WEIGHT
Approx. 75 lbs.
Cooling
Patented Total Liquid Immersion with Directed Flow™ (TIDF)
Operating temperature
32oF-113oF (0oC – 45oC)
Wide operating temperature range enables deployment in almost any environment
Heat exchange options
Liquid-to-liquid
Silent operation
Up to 98% of waste heat captured
Liquid immersion/fan assisted
Install almost anywhere
Compatible with existing server room
Hot/cold isle
Quiet @ <55 dBA
Liquid-to-air (passive radiator)
Nearly silent with options to use waste heat for facility heating applications